MACOM Announces Highest Power Handling and Fastest Recovery Time SPDT Switch-Limiter
Reliable surface mount device is ideal for high power S-Band switch applications and enables repeatable high volume manufacturing
Operating over the 2.7 - 3.5 GHz bandwidth, the device handles 125W of CW power at 85°C while providing ultra fast recovery time of less than 100 nanoseconds. (Photo: Business Wire)
The MASL-011023 is an innovative switch-limiter solution for customers who require the industry's fastest recovery time and highest power handling for S-Band receive protection applications. Operating over the 2.7 - 3.5 GHz bandwidth, the device handles 125W of CW power at 85°C while providing ultra fast recovery time of less than 100 nanoseconds. The switch is offered in a JEDEC standard footprint surface mount 7mm x 7mm QFN package that enables repeatable, high volume manufacturing. The MASL-011023 delivers low insertion loss, high isolation and the lowest available flat leakage of 10 dBm in Rx mode and 7 dBm in Tx mode.
This SP2T switch-limiter is designed to minimize insertion loss and handle +51 dBm CW power through the transmit path. This exceptional device also incorporates a fully integrated RF & DC bias network which provides the customer with a complete switch-limiter solution.
"The combination of highest power handling, lowest flat leakage and
ultra fast recovery time make the MASL-011023 switch-limiter a unique
and attractive solution for receiver protection in radar applications",
said
The table below outlines typical performance:
Parameter | Units | MASL-011023 | |||||||||
Frequency | GHz | 2.7-3.5 | |||||||||
Power Handling Tx Mode | W | 125, CW | |||||||||
Power Handling Rx Mode | W | 2.0, CW | |||||||||
Insertion Loss Rx Mode | dB | 0.85 | |||||||||
Insertion Loss Tx Mode | dB | 0.25 | |||||||||
Return Loss (Rx and Tx Mode) | dB | 14 | |||||||||
Isolation Rx Mode | dB | 30 | |||||||||
Isolation Tx Mode | dB | 17 | |||||||||
Flat Leakage Rx Mode | dBm | 10 | |||||||||
Flat Leakage Tx Mode | dBm | 7 | |||||||||
Limiter Recovery Time to Final Insertion Loss | ns | < 100 |
Production quantities and samples of MASL-011023 are available from stock. Final datasheets and additional product information can be obtained from the MACOM website at: www.macomtech.com
ABOUT
Headquartered in
MACOM,
Photos/Multimedia Gallery Available: http://www.businesswire.com/multimedia/home/20130822005356/en/
For Sales Information:
or
Media:
Husrav Billimoria, 978-656-2896
Husrav.Billimoria@macomtech.com
or
jglockner@rainierco.com
Source:
News Provided by Acquire Media